Device Profiles
Shared radio and MAC settings for groups of LoRaWAN devices.
A device profile defines the radio and protocol behaviour for a group of devices: frequency region, LoRaWAN MAC version, activation method (OTAA or ABP) and Class B / Class C support. Every device must use a profile, so create profiles before adding devices.
The Device profiles tab lists all profiles with their Name, Region, MAC version, OTAA and Class B / Class C support. Use the search to find a profile by name or region.
Add a device profile
Click + Add device profile. The dialog has a navigation on the left: General, Join & activation, Class B, Class C and ABP parameters. The badges next to the items show the current state (e.g. OTAA, Off).

General
Name
Yes
e.g. EU868 OTAA Class A sensors.
Description
No
Optional notes.
Region
Yes
EU868
Frequency plan. Must match your gateways and devices.
MAC version
Yes
LoRaWAN 1.0.3
LoRaWAN version of the devices: 1.0.0, 1.0.1, 1.0.2, 1.0.3, 1.0.4 or 1.1.0.
Regional parameters revision
Yes
A
Regional parameters specification revision supported by the devices (see the device datasheet).
Region config ID
No
Optional, for a specific region configuration of the network server.
Supported regions: EU868, US915, CN779, EU433, AU915, CN470, AS923, AS923-2, AS923-3, AS923-4, KR920, IN865, RU864, ISM2400.
Join & activation

OTAA
On
Over-the-air activation. Turn off for ABP devices.
Flush queue on activate
On
Clear pending downlinks after a (re)join.
Allow roaming
Off
Allow the devices to be served via roaming.
Auto-detect measurements
On
Automatically detect the measurements sent by the devices.
Uplink interval, s
0
Expected interval between uplinks.
Device-status request interval, s
0
How often the server requests the device status (battery, margin).
RX1 delay, s
0
Delay of the first receive window.
ADR algorithm ID
default
Adaptive Data Rate algorithm. Leave empty for the default algorithm.
Class B
Turn on Supports Class B for devices with scheduled receive windows (ping slots). Additional fields appear: Class B timeout, s, Ping-slot periodicity, Ping-slot DR and Ping-slot frequency, Hz.
Class C
Turn on Supports Class C for devices that listen continuously (usually mains-powered, e.g. actuators). Set the Class C timeout, s.
ABP parameters
Used only when OTAA is off: RX1 delay, RX1 DR offset, RX2 DR and RX2 frequency, Hz. Use the values configured in the device firmware.
Click Add profile to save.